Output voltage、current |
|
| |
Output voltage、current |
| 型号 |
+5V |
+3.3V |
+12V |
-5V |
-12V |
+5Vsb |
TOTAL POWER |
+5V&+3.3V(max) |
| PRRD250V-110 |
25A |
15A |
14A |
1A |
1~3A |
1A |
250W |
125W |
| RPRD250V-220 |
25A |
15A |
14A |
1A |
1~3A |
1A |
250W |
125W |
PRRD320V-110 |
32A |
20A |
20A |
1A |
1~3A |
1A |
320W |
160W |
| PRRD320V-220 |
32A |
20A |
20A |
1A |
1~3A |
1A |
320W |
160W |
| PRRD400V-110 |
42A |
20A |
14A |
1A |
1~3A |
1A |
400W |
210W |
| PRRD400V-220 |
42A |
20A |
14A |
1A |
1~3A |
1A |
400W |
210W |
| PRRD401V-110 |
50A |
30A |
27A |
1A |
1~3A |
1A |
400W |
250W |
| RPRD401V-220 |
50A |
30A |
27A |
1A |
1~3A |
1A |
400W |
250W |
Note: PRRDxxxV-100;-220 means I/P +110V,+220V
| 型号 |
+5V |
+3.3V |
+12V |
-5V |
-12V |
+5Vsb |
TOTAL POWER |
+5V&+3.3V(max) |
| PRRD250V |
25A |
15A |
14A |
1A |
1~3A |
1A |
250W |
25A |
| RPRD250V-1 |
25A |
|
14A |
1A |
1~3A |
|
250W |
|
| PRRD250V-A |
25A |
15A |
14A |
1A |
1A |
0.75A |
250W |
25A |
| RPRD250V-1A |
25A |
|
14A |
1A |
1A |
|
250W |
|
PRRD320V |
32A |
20A |
20A |
1A |
1~3A |
1A |
320W |
32A |
| PRRD320V-1 |
32A |
|
20A |
1A |
1~3A |
|
320W |
|
PRRD320V-A |
32A |
20A |
20A |
1A |
1A |
0.75A |
320W |
32W |
| PRRD320V-1A |
32A |
|
20A |
1A |
1A |
|
320W |
|
| PRRD400V |
42A |
20A |
14A |
1A |
1~3A |
1A |
400W |
42A |
| PRRD400V-1 |
42A |
|
14A |
1A |
1~3A |
|
400W |
|
| PRRD401V |
50A |
30A |
27A |
1A |
1~3A |
1A |
400W |
50A |
| RPRD401V-1 |
50A |
|
27A |
1A |
1~3A |
|
400W |
|
Note: PRRDxxxV-A means I/P +24V |
Input Specifications |
●AC Input Voltage :
100~240Vac ± 10% / Active PFC;100-120/200-240Vac ± 10% Auto Range
●Current : 4.0A ~ 10.0A
●Frequency : 50/60Hz, Range 47~63 Hz
●Inrush Current:: 100A max per module @25°C cold star
●Efficiency: >63% at full load ,nominal line input
●Leakage Current: <3.5mA per module
●Hold-Up Time : 16msec (minimum) at full load, nominal line I/P
●Transient Overshoot : 10% max with 20% load change
●Remote ON/OFF: TTL High/PS-OFF;TTL Low/PS-ON
●Power Good Delay : 100~500 msec
●Power Fail : >1 msec
●Rise Time : 100ms max at full load
●Power Up Time :
600ms max at full load. (2000ms max for Active PFC);Protection Specification
●DC Input Voltage : -36VDC ~ 72VDC / 20VDC~32VDC / +110V / +220V
●Current : 11~19A per module
●Inrush Current:: 100A max per module @25°C cold star
●Efficiency: >63% at full load ,nominal line input
●Leakage Current: <3.5mA per module
●Transient Overshoot : 10% max with 20% load change
●Remote ON/OFF: TTL High/PS-OFF;TTL Low/PS-ON
●Power Good Delay : 100~500 msec
●Power Fail : >1 msec
●Rise Time : 100ms max at full load
●Power Up Time:1200ms max at full load. |
|
Protection Specifications
|
|
●Short Circuit : All
output to GND
●Over Power : 150%
●Over Voltage :
+3.3V output 4.10V ± 0.40V
+5.0V output 6.25V ± 0.75V
+12.0V output 14.6V ± 1.00V |
|
Dielectric Withstand Voltage
|
|
●Primary to Secondary
: 1500Vac for 1 minute or 1800Vac for 1 second
●Primary to Earth GND : 1500Vac for 1 minute or 1800Vac for 1 second
●Insulation Resistance : Primary to earth ground – 500Vdc, 50MΩ
|
|
Conducted EMI |
|
●Meet FCC Class A,115Vac
operation
●Meet CISPR22 Class A,230Vac operation |
|
Safety Standards |
|
●UL/CUL : UL60950 3rd.
●TUV : EN60950
●CB : EN60950
●CE :
●CCC:GB4943 |