Output voltage、current |
|
Input Specifications |
|
●Input Voltage : 100~240Vac
± 10% / Active PFC ;100-120/200-240Vac ± 10% Auto Range
●Current : 4.0A~10.0A
●Frequency : 50/60Hz, Range 47~63 Hz
●Efficiency: >63% at full load ,nominal line input
●Leakage Current: <3.5mA
●Hold-Up Time : 16msec (minimum) at full load, nominal line I/P
●Remote ON/OFF: TTL High/PS-OFF;TTL Low/PS-ON
●Power Good Delay : 100~500 msec
●Power Fail : >1 msec
●Rise Time : 100ms max at full load
●Power Up Time : 600ms max at full load. (2000ms max for Active
PFC) |
|
Protection Specifications
|
|
●Short Circuit : All
output to GND
●Over Power : 150%
●Over Voltage :
+3.3V output 4.10V ± 0.40V
+5.0V output 6.25V ± 0.75V
+12.0V output 14.6V ± 1.00V |
|
Dielectric Withstand Voltage
|
|
●Primary to Secondary:1500Vac
for 1 minute or 1800Vac for 1 second
●Primary to Earth GND:1500Vac for 1 minute or 1800Vac for 1 second
●Insulation Resistance : Primary to earth ground – 500Vdc, 50MΩ
|
|
Conducted EMI |
|
●Meet FCC Class B,115Vac
operation
●Meet CISPR22 Class B,230Vac operation |
|
Safety Standards |
|
●UL/CUL : UL60950 3rd.
●TUV : EN60950
●CB : EN60950
●CE
●CCC : GB4943 |